A 24 MVA inverter using IGCT series connection for medium voltage applications
This paper describes a 24 MVA inverter utilizing the series connection of three IGCTs per switch position in a three-level neutral point clamped inverter topology. The electrical design, especially focused on one phase leg, as well as experimental results, are shown.
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper describes a 24 MVA inverter utilizing the series connection of three IGCTs per switch position in a three-level neutral point clamped inverter topology. The electrical design, especially focused on one phase leg, as well as experimental results, are shown. |
---|---|
ISSN: | 0197-2618 2576-702X |
DOI: | 10.1109/IAS.2001.955554 |