Preliminary results obtained from a novel CdZnTe pad detector and readout ASIC developed for an automatic baggage inspection system
A linear CdZnTe pad detector array with approximately 1 mm/sup 2/ pad area has been developed. The detector has a wide energy range from about 20 to 200 keV. A fast, low-noise monolithic mixed signal ASIC chip has been developed to read out these detector arrays. A prototype X-ray imaging system con...
Gespeichert in:
Hauptverfasser: | , , , , , , , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A linear CdZnTe pad detector array with approximately 1 mm/sup 2/ pad area has been developed. The detector has a wide energy range from about 20 to 200 keV. A fast, low-noise monolithic mixed signal ASIC chip has been developed to read out these detector arrays. A prototype X-ray imaging system consisting of the CdZnTe detector array and the monolithic ASIC chip has been fabricated and tested. In this system, the detectors are abutted against each other to form an approximately 1 m long linear array. The system has been used to take preliminary scanned images of complex objects at various energies. New results obtained from this system is discussed. |
---|---|
ISSN: | 1082-3654 2577-0829 |
DOI: | 10.1109/NSSMIC.2000.949044 |