Directional Coupler Calibration for Accurate Online Incident Power Measurements
This letter proposes a calibration method to properly measure the incident power in a directional coupler (DC) when the measurement configuration has low directivity. The proposed method is based on measurements of short-circuits placed at different distances to calibrate the DC response. Results sh...
Gespeichert in:
Veröffentlicht in: | IEEE microwave and wireless components letters 2021-06, Vol.31 (6), p.624-627 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This letter proposes a calibration method to properly measure the incident power in a directional coupler (DC) when the measurement configuration has low directivity. The proposed method is based on measurements of short-circuits placed at different distances to calibrate the DC response. Results show that the method is clearly robust and provides accurate measurements even for directivities as low as 10 dB. |
---|---|
ISSN: | 1531-1309 2771-957X 1558-1764 2771-9588 |
DOI: | 10.1109/LMWC.2021.3070788 |