3D Transient Electromagnetic-Temperature Field Analysis of the Loss and Heat of the Damper Bars of a Large Tubular Hydro-Generator During Short Circuit Faults

This paper studies a real 36-MW large tubular hydro-generator to solve the transient variation problem of the loss and heat of damper bars during short circuit faults in tubular hydro-generators. The transient analysis method of electromagnetic-temperature fields is adopted to study the transient va...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE access 2020, Vol.8, p.135963-135974
Hauptverfasser: Hu, Qing-Ling, Xiao, Ke, Zhou, Zhi-Ting, Fan, Zhen-Nan, Yang, Yong, Bian, Zu-Ying, Li, Jing-Can, Yao, Bing
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper studies a real 36-MW large tubular hydro-generator to solve the transient variation problem of the loss and heat of damper bars during short circuit faults in tubular hydro-generators. The transient analysis method of electromagnetic-temperature fields is adopted to study the transient variation problem of the loss and heat of damper bars during three-phase symmetrical short-circuits, single-phase to ground asymmetrical short-circuits, and phase-to-phase asymmetrical short-circuits under rated operation states. The research work provides valuable findings for improving the level of state analysis, the design and manufacturing processes, and the operation and maintenance of large-scale tubular hydro-generators.
ISSN:2169-3536
2169-3536
DOI:10.1109/ACCESS.2020.3008156