Design of Compact Accelerator Module of the Induction Synchrotron
Induction synchrotron (IS) has become the focus of improving the intensity of high energy ion beams in recent years. But because of the pulse voltage of the induction accelerating cell cannot adjust quickly, causing the mismatch of the magnetic deflection field and accelerate electric field, there i...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on plasma science 2019-03, Vol.47 (3), p.1637-1640 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Induction synchrotron (IS) has become the focus of improving the intensity of high energy ion beams in recent years. But because of the pulse voltage of the induction accelerating cell cannot adjust quickly, causing the mismatch of the magnetic deflection field and accelerate electric field, there is a serious beam loss problem in IS. The simulation of beams longitude dynamics proves that increasing the number of accelerating cells can effectively reduce the loss. In this paper, a novel compact induction accelerator module is introduced. Compared with the existing induction accelerator module of KEK, the new design can increase the number of accelerating cells to more than five times in the same installation space and improves the voltage top drop of the acceleration pulse significantly. |
---|---|
ISSN: | 0093-3813 1939-9375 |
DOI: | 10.1109/TPS.2019.2893502 |