Electrode-induced nonuniformities in the sweeping of alpha quartz

Infrared absorption and scanning electron microscopic techniques show that color-center and/or electrode-metal introduction into quartz is influenced by the porosity of evaporated metal electrodes. Thermal-stress relief of electrode-metal films, during sweeping, normally causes porosity. If the poro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 1991-09, Vol.38 (5), p.486-493
Hauptverfasser: Gualtieri, J.G., Kosinski, J.A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Infrared absorption and scanning electron microscopic techniques show that color-center and/or electrode-metal introduction into quartz is influenced by the porosity of evaporated metal electrodes. Thermal-stress relief of electrode-metal films, during sweeping, normally causes porosity. If the porosity is extensive, H introduction predominates and color-center and electrode-metal introduction mechanisms are suppressed. Samples swept with evaporated Au/Cr electrodes relying on thermal stress-induced porosity sometimes displayed these sweeping nonuniformities. Nonuniformities were not found when samples were swept using evaporated Au-Cr electrodes containing periodic stripe openings. Uniform sweeping was also obtained using magnetron-sputtered amorphous Y-Ba-Cu-O films.< >
ISSN:0885-3010
1525-8955
DOI:10.1109/58.84294