Magnetic Field Measurement and Analysis of the CSNS/RCS Quadrupole Magnets

The China Spallation Neutron Source/rapid-cycling synchrotron (CSNS/RCS) quadrupole magnets excited by both dc current and 25 Hz ac biased dc current were tested and measured in the past two years. All the magnets had been installed in the tunnel by the end of December, 2015. The challenges of the f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on applied superconductivity 2018-04, Vol.28 (3), p.1-4
Hauptverfasser: Li, Li, Kang, Wen, Deng, ChangDong, Li, Shuai, Liu, YiQin, Zhou, JianXin, Wu, YuWen, Wu, Xi, Yin, BaoGui
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The China Spallation Neutron Source/rapid-cycling synchrotron (CSNS/RCS) quadrupole magnets excited by both dc current and 25 Hz ac biased dc current were tested and measured in the past two years. All the magnets had been installed in the tunnel by the end of December, 2015. The challenges of the field measurements included the measurement repeatability of the dc field and the time harmonic measurement of the dc+ac field. The paper will summarize the results of the dc field measurement and the dc+ac field measurement, the key techniques of the rotating coil fabrication and the measurement stability for the CSNS/RCS quadrupole magnets.
ISSN:1051-8223
1558-2515
DOI:10.1109/TASC.2018.2804357