Dynamic MRI Using SmooThness Regularization on Manifolds (SToRM)

We introduce a novel algorithm to recover real time dynamic MR images from highly under-sampled k- t space measurements. The proposed scheme models the images in the dynamic dataset as points on a smooth, low dimensional manifold in high dimensional space. We propose to exploit the non-linear and no...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on medical imaging 2016-04, Vol.35 (4), p.1106-1115
Hauptverfasser: Poddar, Sunrita, Jacob, Mathews
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We introduce a novel algorithm to recover real time dynamic MR images from highly under-sampled k- t space measurements. The proposed scheme models the images in the dynamic dataset as points on a smooth, low dimensional manifold in high dimensional space. We propose to exploit the non-linear and non-local redundancies in the dataset by posing its recovery as a manifold smoothness regularized optimization problem. A navigator acquisition scheme is used to determine the structure of the manifold, or equivalently the associated graph Laplacian matrix. The estimated Laplacian matrix is used to recover the dataset from undersampled measurements. The utility of the proposed scheme is demonstrated by comparisons with state of the art methods in multi-slice real-time cardiac and speech imaging applications.
ISSN:0278-0062
1558-254X
DOI:10.1109/TMI.2015.2509245