Performance and Aging of a 20-Year-Old Silicon PV System
This paper examines the long-term performance of a 20-year-old crystalline silicon system. The degradation was found to be about 0.8%/year and is consistent with historical averages. In contrast with the majority of historical degradation, the decline for this particular system is more attributable...
Gespeichert in:
Veröffentlicht in: | IEEE Journal of Photovoltaics 2015-05, Vol.5 (3), p.744-751 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper examines the long-term performance of a 20-year-old crystalline silicon system. The degradation was found to be about 0.8%/year and is consistent with historical averages. In contrast with the majority of historical degradation, the decline for this particular system is more attributable to fill factor (FF) than to short-circuit current (Isc). The underlying cause was determined to be an increase in series resistance. We found no evidence that this system degrades significantly differently from its worst performing strings and modules. Maintenance events during the 20 years were dominated by inverter issues with a total of four replacements. |
---|---|
ISSN: | 2156-3381 2156-3403 |
DOI: | 10.1109/JPHOTOV.2015.2396360 |