Imperfect quarter-waveplate compensation in Sagnac interferometer-type current sensors
We analyze scale factor errors associated with integrating imperfect quarter-waveplates into loop and in-line Sagnac interferometer fiber-optic current sensors. We show that relatively large imperfections in the quarter-waveplates can be tolerated in the loop version when the birefringence axes of t...
Gespeichert in:
Veröffentlicht in: | Journal of lightwave technology 1998-07, Vol.16 (7), p.1212-1219 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We analyze scale factor errors associated with integrating imperfect quarter-waveplates into loop and in-line Sagnac interferometer fiber-optic current sensors. We show that relatively large imperfections in the quarter-waveplates can be tolerated in the loop version when the birefringence axes of the two quarter-waveplates are oriented 45/spl deg/ with respect to each other. For the in-line version, we demonstrate an electronic signal processing scheme that desensitizes the scale factor to imperfections in the quarter-waveplate. |
---|---|
ISSN: | 0733-8724 1558-2213 |