Performance limitations for unstable SISO plants
This paper examines the fundamental limitations imposed by instability in the plant (right half plane, RHP, poles) on closed-loop performance. The main limitation is that instability requires active use of plant inputs, and we quantify this is terms of tight lower bounds on the input magnitudes requ...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper examines the fundamental limitations imposed by instability in the plant (right half plane, RHP, poles) on closed-loop performance. The main limitation is that instability requires active use of plant inputs, and we quantify this is terms of tight lower bounds on the input magnitudes required for disturbance and measurement noise rejection. These new bounds involve the H/sub /spl infin//-norm, which has direct engineering significance. The output performance in terms of disturbance rejection or reference tracking is only limited if the plant has RHP zeros. It is important to stress that the derived bounds are controller independent and that they are tight, meaning that there exists controllers which achieve the lower bounds. |
---|---|
ISSN: | 0743-1619 2378-5861 |
DOI: | 10.1109/ACC.1998.688461 |