Sampling period online adjusting-based hysteresis current control without band with constant switching frequency

In this paper, a simple digital hysteresis current control (DHCC) with quasi-constant switching frequency (SF) for the current control of a single-phase grid-connected inverter (SPGI) is proposed. The hysteresis band is cancelled, and the SF is fixed by online adjusting the sampling period. The prin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industrial electronics (1982) 2015-01, Vol.62 (1), p.270-277
Hauptverfasser: Wu, Fengjiang, Feng, Fan, Luo, Linsong, Duan, Jiandong, Sun, Li
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, a simple digital hysteresis current control (DHCC) with quasi-constant switching frequency (SF) for the current control of a single-phase grid-connected inverter (SPGI) is proposed. The hysteresis band is cancelled, and the SF is fixed by online adjusting the sampling period. The principle of the DHCC with constant sampling period is analyzed, and the distribution of the switching period (SP) corresponding to the phase angle of the grid is derived. The rule of online adjusting the sampling period to fix SF is then determined according to the former theoretical analysis results. Furthermore, the effect of variation of the filter inductor on the SP is analyzed. An online estimation of the filter inductor based on the linear model of the current increment within one switching cycle is developed to eliminate this kind of effect. The proposed scheme shows the features of simple control, easy implementation in a digital way, robust to the filter inductor, and excellent steady and dynamic performance. The detailed simulation and experimental results verify its accuracy and feasibility.
ISSN:0278-0046
1557-9948
DOI:10.1109/TIE.2014.2326992