Excess Loss Localization on the Hysteresis Curve

Two alloys of nonoriented electrical steel, with 2.45 and 3.3%Si, respectively, had their magnetic properties characterized in an Epstein frame. Hysteresis curves for total, quasi-static, and parasitic losses were plotted and overlapped to identify the region where the anomalous loss happens. It was...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on magnetics 2014-04, Vol.50 (4), p.1-4
Hauptverfasser: Almeida, Adriano A., Perassa, Laura S., Rodrigues, Daniel L., Nishikawa, Thomas S. P., Landgraf, Fernando J. G., Paolinelli, Sebastiao C., Martins, Ramon V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Two alloys of nonoriented electrical steel, with 2.45 and 3.3%Si, respectively, had their magnetic properties characterized in an Epstein frame. Hysteresis curves for total, quasi-static, and parasitic losses were plotted and overlapped to identify the region where the anomalous loss happens. It was observed that most anomalous loss is from the domain wall movement's region and a smaller contribution from nucleation and annihilation regions.
ISSN:0018-9464
1941-0069
DOI:10.1109/TMAG.2013.2291836