Proximity effect scaling in infinitely long coils

Summary form only given. Magnetic field does not diffuse uniformly into helical coils, such as those used in explosive magnetocumulative generators (MCGs). One cause is the proximity of adjacent coils, which perturbs the magnetic field and the subsequent diffusion. This can lead to increased resisti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lileikis, M.D., Turchi, P.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Summary form only given. Magnetic field does not diffuse uniformly into helical coils, such as those used in explosive magnetocumulative generators (MCGs). One cause is the proximity of adjacent coils, which perturbs the magnetic field and the subsequent diffusion. This can lead to increased resistive losses in the MCGs. This poster presents the results of an axisymmetric magnetic diffusion solver, and provides a method to estimate the additional resistive losses associated with the proximity effect. The proximity factor is calculated using a dissipation-based approach.
ISSN:0730-9244
2576-7208
DOI:10.1109/PLASMA.1998.677539