Active damping of LCL filter without capacitor voltage sensors for three phase PWM inverter
In this paper, new sensorless active damping method of the grid-connected LCL filter for a three-phase PWM inverter is proposed. The resonance component of capacitor voltage of LCL filter is observed by a simple MRAS (Model Reference Adaptive System) observer without additional sensors or circuits....
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, new sensorless active damping method of the grid-connected LCL filter for a three-phase PWM inverter is proposed. The resonance component of capacitor voltage of LCL filter is observed by a simple MRAS (Model Reference Adaptive System) observer without additional sensors or circuits. The active damping is implemented by feed-forward compensation of the observed capacitor voltage for current controller. The validity of the proposed method is verified by the simulation and experiment. |
---|---|
ISSN: | 1553-572X |
DOI: | 10.1109/IECON.2013.6700317 |