Effect of cooling on the probe system sensitivity for low signal strength RFI problems

Only highly sensitive probe systems can detect the weak field strengths that cause radio-frequency-interference (RFI) problems typically found within cell phones. The sensitivity of the probe systems depends on the probe factor and on the noise floor. The effect of cooling by liquid nitrogen on the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Guang-Hua Li, Wei Huang, Pommerenke, David
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Only highly sensitive probe systems can detect the weak field strengths that cause radio-frequency-interference (RFI) problems typically found within cell phones. The sensitivity of the probe systems depends on the probe factor and on the noise floor. The effect of cooling by liquid nitrogen on the received signal strength and the noise floor of three resonant probe systems has been investigated. They operate at the GSM, GPS, and WiFi frequency bands. Cooling increases the Q-factor of these resonant probes, increases the received signal, and lowers the noise floor. The sensitivity of the system, defined as the signal strength at which the Signal-to-Noise Ratio is equal to 0 dB improves by 3-6 dB.
ISSN:2158-110X
2158-1118
DOI:10.1109/ISEMC.2013.6670396