Influence of sample preparation on space charge behavior of crosslinked polyethylene for HVDC cables
The aim of this study is to demonstrate how the space charge behavior can be dependent on the choice of sample preparation and electrode configuration. The space charge behavior of crosslinked polyethylene (XLPE) has been investigated by measuring with the pulsed electro acoustic method on plaque sa...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study is to demonstrate how the space charge behavior can be dependent on the choice of sample preparation and electrode configuration. The space charge behavior of crosslinked polyethylene (XLPE) has been investigated by measuring with the pulsed electro acoustic method on plaque samples from both pellets and pre-extruded tape and tested with three different electrode configurations. The result revealed that different types of plaque preparation had a clear impact on the space charge data at elevated test temperature, whereas the effect from electrode configuration could be seen even at room temperature. |
---|---|
ISSN: | 1553-5282 2159-1687 |
DOI: | 10.1109/ICSD.2013.6619844 |