NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results

National Physical Laboratory India has developed a cesium atomic fountain frequency standard. The fountain has now become operational and is ready for complete frequency evaluation. In this paper, we report for the first time, the preliminary results obtained with this fountain, which include Ramsey...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on instrumentation and measurement 2013-07, Vol.62 (7), p.2037-2042
Hauptverfasser: Arora, P., Purnapatra, S. B., Acharya, A., Agarwal, A., Yadav, S., Pant, K., Gupta, A. S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2042
container_issue 7
container_start_page 2037
container_title IEEE transactions on instrumentation and measurement
container_volume 62
creator Arora, P.
Purnapatra, S. B.
Acharya, A.
Agarwal, A.
Yadav, S.
Pant, K.
Gupta, A. S.
description National Physical Laboratory India has developed a cesium atomic fountain frequency standard. The fountain has now become operational and is ready for complete frequency evaluation. In this paper, we report for the first time, the preliminary results obtained with this fountain, which include Ramsey fringes, frequency stability analysis, with an H-maser, and magnetic field mapping in the atomic flight region.
doi_str_mv 10.1109/TIM.2013.2255974
format Article
fullrecord <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_6509912</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6509912</ieee_id><sourcerecordid>10_1109_TIM_2013_2255974</sourcerecordid><originalsourceid>FETCH-LOGICAL-c263t-9cbf072be659c54a9b4786e75a9dac1e9e1a03e3d154940a68a5593664a9281b3</originalsourceid><addsrcrecordid>eNo9kE1Lw0AYhBdRsFbvgpf9A6nvfme9lWBrIWrReg6bzVtYaVLdTQ7996a0eJrLzDDzEHLPYMYY2MfN6nXGgYkZ50pZIy_IhCllMqs1vyQTAJZnVip9TW5S-gYAo6WZkOJtXa5ogSkMLZ33-zZ4utgPXe9CRxcRfwfs_IF-9q5rXGye6DriLrShc_FAPzANuz7dkqut2yW8O-uUfC2eN8VLVr4vV8W8zDzXos-sr7dgeI1aWa-ks7U0uUajnG2cZ2iRORAoGqakleB07sYnQuvRynNWiymBU6-P-5QibqufGNpxSMWgOkKoRgjVEUJ1hjBGHk6RgIj_dq3AWsbFH3sdV7g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results</title><source>IEEE Electronic Library (IEL)</source><creator>Arora, P. ; Purnapatra, S. B. ; Acharya, A. ; Agarwal, A. ; Yadav, S. ; Pant, K. ; Gupta, A. S.</creator><creatorcontrib>Arora, P. ; Purnapatra, S. B. ; Acharya, A. ; Agarwal, A. ; Yadav, S. ; Pant, K. ; Gupta, A. S.</creatorcontrib><description>National Physical Laboratory India has developed a cesium atomic fountain frequency standard. The fountain has now become operational and is ready for complete frequency evaluation. In this paper, we report for the first time, the preliminary results obtained with this fountain, which include Ramsey fringes, frequency stability analysis, with an H-maser, and magnetic field mapping in the atomic flight region.</description><identifier>ISSN: 0018-9456</identifier><identifier>EISSN: 1557-9662</identifier><identifier>DOI: 10.1109/TIM.2013.2255974</identifier><identifier>CODEN: IEIMAO</identifier><language>eng</language><publisher>IEEE</publisher><subject>Atomic clocks ; Atomic measurements ; Cavity resonators ; Cooling ; Laser beams ; Magnetometers ; microwave frequency standard ; Ramsey fringes</subject><ispartof>IEEE transactions on instrumentation and measurement, 2013-07, Vol.62 (7), p.2037-2042</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c263t-9cbf072be659c54a9b4786e75a9dac1e9e1a03e3d154940a68a5593664a9281b3</citedby><cites>FETCH-LOGICAL-c263t-9cbf072be659c54a9b4786e75a9dac1e9e1a03e3d154940a68a5593664a9281b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6509912$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>315,781,785,797,27926,27927,54760</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6509912$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Arora, P.</creatorcontrib><creatorcontrib>Purnapatra, S. B.</creatorcontrib><creatorcontrib>Acharya, A.</creatorcontrib><creatorcontrib>Agarwal, A.</creatorcontrib><creatorcontrib>Yadav, S.</creatorcontrib><creatorcontrib>Pant, K.</creatorcontrib><creatorcontrib>Gupta, A. S.</creatorcontrib><title>NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results</title><title>IEEE transactions on instrumentation and measurement</title><addtitle>TIM</addtitle><description>National Physical Laboratory India has developed a cesium atomic fountain frequency standard. The fountain has now become operational and is ready for complete frequency evaluation. In this paper, we report for the first time, the preliminary results obtained with this fountain, which include Ramsey fringes, frequency stability analysis, with an H-maser, and magnetic field mapping in the atomic flight region.</description><subject>Atomic clocks</subject><subject>Atomic measurements</subject><subject>Cavity resonators</subject><subject>Cooling</subject><subject>Laser beams</subject><subject>Magnetometers</subject><subject>microwave frequency standard</subject><subject>Ramsey fringes</subject><issn>0018-9456</issn><issn>1557-9662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kE1Lw0AYhBdRsFbvgpf9A6nvfme9lWBrIWrReg6bzVtYaVLdTQ7996a0eJrLzDDzEHLPYMYY2MfN6nXGgYkZ50pZIy_IhCllMqs1vyQTAJZnVip9TW5S-gYAo6WZkOJtXa5ogSkMLZ33-zZ4utgPXe9CRxcRfwfs_IF-9q5rXGye6DriLrShc_FAPzANuz7dkqut2yW8O-uUfC2eN8VLVr4vV8W8zDzXos-sr7dgeI1aWa-ks7U0uUajnG2cZ2iRORAoGqakleB07sYnQuvRynNWiymBU6-P-5QibqufGNpxSMWgOkKoRgjVEUJ1hjBGHk6RgIj_dq3AWsbFH3sdV7g</recordid><startdate>20130701</startdate><enddate>20130701</enddate><creator>Arora, P.</creator><creator>Purnapatra, S. B.</creator><creator>Acharya, A.</creator><creator>Agarwal, A.</creator><creator>Yadav, S.</creator><creator>Pant, K.</creator><creator>Gupta, A. S.</creator><general>IEEE</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20130701</creationdate><title>NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results</title><author>Arora, P. ; Purnapatra, S. B. ; Acharya, A. ; Agarwal, A. ; Yadav, S. ; Pant, K. ; Gupta, A. S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c263t-9cbf072be659c54a9b4786e75a9dac1e9e1a03e3d154940a68a5593664a9281b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Atomic clocks</topic><topic>Atomic measurements</topic><topic>Cavity resonators</topic><topic>Cooling</topic><topic>Laser beams</topic><topic>Magnetometers</topic><topic>microwave frequency standard</topic><topic>Ramsey fringes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Arora, P.</creatorcontrib><creatorcontrib>Purnapatra, S. B.</creatorcontrib><creatorcontrib>Acharya, A.</creatorcontrib><creatorcontrib>Agarwal, A.</creatorcontrib><creatorcontrib>Yadav, S.</creatorcontrib><creatorcontrib>Pant, K.</creatorcontrib><creatorcontrib>Gupta, A. S.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><jtitle>IEEE transactions on instrumentation and measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Arora, P.</au><au>Purnapatra, S. B.</au><au>Acharya, A.</au><au>Agarwal, A.</au><au>Yadav, S.</au><au>Pant, K.</au><au>Gupta, A. S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results</atitle><jtitle>IEEE transactions on instrumentation and measurement</jtitle><stitle>TIM</stitle><date>2013-07-01</date><risdate>2013</risdate><volume>62</volume><issue>7</issue><spage>2037</spage><epage>2042</epage><pages>2037-2042</pages><issn>0018-9456</issn><eissn>1557-9662</eissn><coden>IEIMAO</coden><abstract>National Physical Laboratory India has developed a cesium atomic fountain frequency standard. The fountain has now become operational and is ready for complete frequency evaluation. In this paper, we report for the first time, the preliminary results obtained with this fountain, which include Ramsey fringes, frequency stability analysis, with an H-maser, and magnetic field mapping in the atomic flight region.</abstract><pub>IEEE</pub><doi>10.1109/TIM.2013.2255974</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9456
ispartof IEEE transactions on instrumentation and measurement, 2013-07, Vol.62 (7), p.2037-2042
issn 0018-9456
1557-9662
language eng
recordid cdi_ieee_primary_6509912
source IEEE Electronic Library (IEL)
subjects Atomic clocks
Atomic measurements
Cavity resonators
Cooling
Laser beams
Magnetometers
microwave frequency standard
Ramsey fringes
title NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T09%3A31%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=NPLI%20Cesium%20Atomic%20Fountain%20Frequency%20Standard:%20Preliminary%20Results&rft.jtitle=IEEE%20transactions%20on%20instrumentation%20and%20measurement&rft.au=Arora,%20P.&rft.date=2013-07-01&rft.volume=62&rft.issue=7&rft.spage=2037&rft.epage=2042&rft.pages=2037-2042&rft.issn=0018-9456&rft.eissn=1557-9662&rft.coden=IEIMAO&rft_id=info:doi/10.1109/TIM.2013.2255974&rft_dat=%3Ccrossref_RIE%3E10_1109_TIM_2013_2255974%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6509912&rfr_iscdi=true