Impact of trace spacing on noise coupling for guard trace in stripline structure
This work investigates how the noise coupling is affected for a guard trace with different trace spacings in stripline structure. For a guard trace maintaining the same trace separation, although reducing crosstalk noise can achieve good efficiency, a guard trace with different trace spacings induce...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This work investigates how the noise coupling is affected for a guard trace with different trace spacings in stripline structure. For a guard trace maintaining the same trace separation, although reducing crosstalk noise can achieve good efficiency, a guard trace with different trace spacings induces residual crosstalk voltage on the guard trace. Residual crosstalk voltage can be regarded as a main signal and capable of inducing a significant amount of extra crosstalk noise at both the near end and far end on the victim line. To address this issue, 3D full-wave simulation is performed. Compared to the same trace spacing, due to the different trace spacings, the increasing amount of magnitude of time-domain crosstalk noises exceeds 70 % on the victim line. Additionally, in the frequency domain, the increasing amount of magnitude of the first and largest resonant crosstalk peak at about 1GHz is more 25dB. |
---|---|
ISSN: | 2165-4727 2165-4743 |