Characterization and testing of PZLT ferroelectric ceramics with two Pt implants
Recently, a new PLZT bulk single plate, called ceramic-controlled piezoelectric with two Pt wires (CCP2) has been produced; this CCP2 has two (300 μm of diameter and 1 cm long) Pt-wire implants. These isolation was validated using four experimental setups, one of them determine that ceramic-controll...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Recently, a new PLZT bulk single plate, called ceramic-controlled piezoelectric with two Pt wires (CCP2) has been produced; this CCP2 has two (300 μm of diameter and 1 cm long) Pt-wire implants. These isolation was validated using four experimental setups, one of them determine that ceramic-controlled piezoelectric with two Pt wires (CCP2) support up to 6 kV DC before it cracks (short cut). The second experimental setup determined high resistance about 3.9×10 9 Ω and 1.8×10 9 Ω measured on lateral sides and among Pt wires of CCP2 respectively. The third experimental setup was to obtain the current leakage from CCP2 and it was 6 nA. The fourth experimental setup was to obtain frequency response that was the maximum up to 2.2 MHz and was a pass band filter. |
---|---|
DOI: | 10.1109/ICEEE.2012.6421141 |