The aurora reflex-diode HPM source

This status report on the ongoing reflex-diode microwave source on Aurora documents the production of ~ 400 J microwave pulses below 1.0 GHz in pulses lasting ~ 100 ns. The energy is measured in radial waveguides. The diagnostics include waveguide directional couplers, waveguide card calorimeters, a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Huttlin, G. A., Agee, F. J., Bushell, M. S., Conrad, D. B., Davis, D. P., Judy, D. C., Litz, M. S., Ruth, B. G., Ebersole, K. L., Lezcano, P. A., Pereira, N. R., Weidenheimer, D. M.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This status report on the ongoing reflex-diode microwave source on Aurora documents the production of ~ 400 J microwave pulses below 1.0 GHz in pulses lasting ~ 100 ns. The energy is measured in radial waveguides. The diagnostics include waveguide directional couplers, waveguide card calorimeters, and free-field antennas. The energy extracted per arm is independent of the number of arms (up to eight). Attempts at increasing the microwave energy by varying anode material, anode/cathode spacing, or cavity length around the virtual cathode are inconclusive. Thin aluminum anode foils survive tens of shots without damage.