Comparison of fixed speed wind turbines models: A case study

This paper presents a model comparison of a fixed speed wind turbine (FSWT) operating on a real wind farm. By relying on real data obtained from a wind farm operating in the Chilean Interconnected System, three different models are identified and analyzed. First, a phenomenological model based on ph...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bustos, G., Vargas, L. S., Milla, F., Saez, D., Zareipour, H., Nunez, A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents a model comparison of a fixed speed wind turbine (FSWT) operating on a real wind farm. By relying on real data obtained from a wind farm operating in the Chilean Interconnected System, three different models are identified and analyzed. First, a phenomenological model based on physical principles governing the production of electricity from wind power is considered. This model is fine-tuned in accordance with practical considerations, such as wind correction factors. Then, a linear model and a Takagi & Sugeno (T&S) fuzzy model are identified. From the experimental results, the linear model is the simplest one, but also the one that presents the worst performance indexes. The best prediction capability is obtained with the T&S model; however, in terms of interpretability, the phenomenological model outperforms the other two black-box models.
ISSN:1553-572X
DOI:10.1109/IECON.2012.6388937