Coupling interface circuit design for experimental characterization of the narrowband power line communication channel

This paper presents the design of an appropriate coupling interface circuit for measuring indoor power line transmission channel characteristics in CENELEC/FCC/ARIB low-frequency bands. This coupling circuit prevents the powerful and damaging 50 Hz/220 V current from entering sensitive measurement e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gassara, H., Bali, M. C., Duval, F., Rouissi, F., Ghazel, A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents the design of an appropriate coupling interface circuit for measuring indoor power line transmission channel characteristics in CENELEC/FCC/ARIB low-frequency bands. This coupling circuit prevents the powerful and damaging 50 Hz/220 V current from entering sensitive measurement equipments while allowing narrowband PLC signals reception. It also guarantees impedance matching and instruments protection from very large voltage spikes and fast transients. Tests following EN 50065-2-3 standard [1] are done to verify that the proposed coupling interface provides a high safety level and is in compliance with immunity requirements.
ISSN:2158-110X
2158-1118
DOI:10.1109/ISEMC.2012.6351760