Chasing a latent CDM ESD failure by unconventional FA methodology
A hard-to-detect functional CDM ESD failure caused by an obscure charge trapping phenomenon on an advanced CMOS IC is described while no physical damage was evident. Advancing failure analysis method by localized thermal LASER annealing and applying analytical ESD test plan led to successful localiz...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A hard-to-detect functional CDM ESD failure caused by an obscure charge trapping phenomenon on an advanced CMOS IC is described while no physical damage was evident. Advancing failure analysis method by localized thermal LASER annealing and applying analytical ESD test plan led to successful localization of the root cause. |
---|---|
ISSN: | 0739-5159 2164-9340 |