I-V curves and visual inspection of 250 PV modules deployed over 2 years in tucson
To study degradation of PV systems, we measured current-voltage (I-V) curves from 250 modules that have been deployed in grid-tied systems for 2 to 12 years in Arizona. We also documented visual signs of weathering. The I-V curves exhibit a variety of imperfections and considerable dispersion of P m...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To study degradation of PV systems, we measured current-voltage (I-V) curves from 250 modules that have been deployed in grid-tied systems for 2 to 12 years in Arizona. We also documented visual signs of weathering. The I-V curves exhibit a variety of imperfections and considerable dispersion of P max values. Although many of these modules appear weathered, we found few significant correlations between visible signs of weathering and lower P max values, and the most degraded modules have no correlation between visual defects and performance. This indicates that important forms of degradation can remain hidden to the eye. |
---|---|
ISSN: | 0160-8371 |