Optimized design and implementation of low-cost, sensitive and versatile Vibrating Sample Magnetometer
Geometry of different electromagnetic parts of Vibrating Sample Magnetometer (VSM) is a major factor of VSM output voltage. In this paper design, geometry optimization and implementation of a sensitive, versatile and relatively inexpensive VSM system has been described. Considering all effective geo...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Geometry of different electromagnetic parts of Vibrating Sample Magnetometer (VSM) is a major factor of VSM output voltage. In this paper design, geometry optimization and implementation of a sensitive, versatile and relatively inexpensive VSM system has been described. Considering all effective geometrical parameters in the system output voltage, the induced voltage in the pick-up coils has been obtained analytically and the geometry of the pick-up coils has been optimized for maximum output induced voltage. Two opposite series of pick-up coils, piezoelectric based vibration system and required electronic circuits have been designed and the VSM system has been implemented. The implemented optimized VSM system has been used to reveal magnetization loop of ferromagnetic materials. |
---|---|
ISSN: | 2164-7054 |
DOI: | 10.1109/IranianCEE.2012.6292353 |