Wideband guarded inductive divider for linearity test in synchronized generators

A modified version of wideband inductive divider with guarded cable connections has been built for testing the linearity in multiphase generators. The operative frequency is 500 Hz - 50 kHz for voltage up to 10 V, where it can be calibrated with suitable procedures. Simulation with a lumped paramete...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Pogliano, U., Trinchera, B., Serazio, D.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A modified version of wideband inductive divider with guarded cable connections has been built for testing the linearity in multiphase generators. The operative frequency is 500 Hz - 50 kHz for voltage up to 10 V, where it can be calibrated with suitable procedures. Simulation with a lumped parameters circuit has shown that the errors both in phase and quadrature are within 3 parts in 10 6 .
ISSN:0589-1485
2160-0171
DOI:10.1109/CPEM.2012.6251024