A bilateral comparison between NIST quantum-based power standard and NRC current-comparator-based power standard
The results of a bilateral comparison on active/reactive power meter calibrations between the National Institute of Standards and Technology (NIST) and the National Research Council (NRC) will be presented. The comparison was implemented using a transfer standard consisting of a highly stable commer...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The results of a bilateral comparison on active/reactive power meter calibrations between the National Institute of Standards and Technology (NIST) and the National Research Council (NRC) will be presented. The comparison was implemented using a transfer standard consisting of a highly stable commercial sampling-type power/energy meter. The measurements were made at 120 V, 5A, 50 Hz and 60 Hz, at power factors of 1.0, 0.5 lead and lag, and 0.0 lead and lag. |
---|---|
ISSN: | 0589-1485 2160-0171 |
DOI: | 10.1109/CPEM.2012.6250872 |