Measurements of high voltage across the vacuum diode of a high-current generator by using photoneutron reactions

A new method is proposed for measuring the voltage across the vacuum diode of a high-current generator by determining the high-energy edge of bremsstrahlung from an electron beam with the help of photoneutron reactions. The method is approved in the RS-20 facility with a plasma opening switch in the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Dan'ko, Seregej A., Dolgachev, Georgy I., Kalinin, Yury G., Maslennikov, Dmitry D.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A new method is proposed for measuring the voltage across the vacuum diode of a high-current generator by determining the high-energy edge of bremsstrahlung from an electron beam with the help of photoneutron reactions. The method is approved in the RS-20 facility with a plasma opening switch in the voltage range 2.5÷4.5 MV. The results obtained by using this technique are in good agreement with the data from electrotechnical measurements.