A new target and detector for high-density magnetic recording channels
A new equalization target for the high-density magnetic recording channel is proposed based on the PR1 partial response combined with decision feedback. A detector for the new target is developed and shown to allow practical implementation. The performance of the detector is assessed through analysi...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on magnetics 1997-09, Vol.33 (5), p.4385-4391 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new equalization target for the high-density magnetic recording channel is proposed based on the PR1 partial response combined with decision feedback. A detector for the new target is developed and shown to allow practical implementation. The performance of the detector is assessed through analysis and simulation. It is shown that the detector is suitable for channel recording densities of 3 bits per PW/sub 50/. |
---|---|
ISSN: | 0018-9464 1941-0069 |