Performance of the high gradient, large aperture quadrupoles for the NSCL superconducting spectrometer

Two superconducting quadrupoles, for use as spectrometer elements, have been constructed and mapped. A sextupole, which is within one of the quadrupoles, has been mounted on the helium vessel bore tube. All the elements are assembled into the same cryostat. The mapped results, obtained with a three...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on applied superconductivity 1997-06, Vol.7 (2), p.610-613
Hauptverfasser: Zhang, B., Zeller, A.F., Bricker, S., Burleigh, R., DeKamp, J.C., Johnson, P., Sherrill, B., Swanson, R., Zink, R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Two superconducting quadrupoles, for use as spectrometer elements, have been constructed and mapped. A sextupole, which is within one of the quadrupoles, has been mounted on the helium vessel bore tube. All the elements are assembled into the same cryostat. The mapped results, obtained with a three axis Hall probe, are compared to 3-dimensional calculations over the entire range of operation. Operation experience and heat loads are presented.
ISSN:1051-8223
1558-2515
DOI:10.1109/77.614578