Analysis of open-phase degradation in a mono-inverter double PMSM system

This paper presents the studies of degradation mechanisms in a mono-inverter multi-machine permanent magnet synchronous (PMS) system subjected to stator phase disconnection. The system principle operation in normal condition will first be presented. The degradation scenarios and their consequences f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Chhun, L., Maussion, P., Pietrzak-David, M., Fadel, M.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents the studies of degradation mechanisms in a mono-inverter multi-machine permanent magnet synchronous (PMS) system subjected to stator phase disconnection. The system principle operation in normal condition will first be presented. The degradation scenarios and their consequences for motor phase and inverter phase disconnection modes will be analyzed in detail. Control solutions under the given degraded condition are also proposed and based on analytical method and Saber simulations. This study contributes to the availability improvement of multi-motor/mono-inverter system.
ISSN:1553-572X
DOI:10.1109/IECON.2011.6119359