Metrological Performance of a Ferrimagnetic Resonance Marker for the Field Control of the CERN Proton Synchrotron
In particle accelerators, "field markers" provide a digital trigger when the magnetic field crosses a given threshold. In this paper, the metrological characterization of a magnetic field marker, based on a ferrimagnetic resonance transducer referencing the flux sensed by a coil, is report...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2012-06, Vol.22 (3), p.9001904-9001904 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In particle accelerators, "field markers" provide a digital trigger when the magnetic field crosses a given threshold. In this paper, the metrological characterization of a magnetic field marker, based on a ferrimagnetic resonance transducer referencing the flux sensed by a coil, is reported. The experimental results of a validation test campaign at the European Organization for Nuclear Research (CERN) to test the marker in static as well as fast ramping fields (up to 2.5 T/s) are illustrated. The repeatability of attained in the range (60 to 100) mT is very promising to increase the performance of the Proton Synchrotron accelerator at CERN. |
---|---|
ISSN: | 1051-8223 1558-2515 |
DOI: | 10.1109/TASC.2011.2179410 |