Pulsed magnetic flux leakage sensor systems and applications

Pulsed magnetic flux leakage (PMFL) technology shows potential advantages in the detection of corrosion, cracks and other defects of ferromagnetic plates or pipeline. A PMFL sensor with new structure is proposed based on the simulation for a variety of different structure sensors. It reduces the mag...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Tao Zhang, Guiyun Tian, Xianzhang Zuo
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Pulsed magnetic flux leakage (PMFL) technology shows potential advantages in the detection of corrosion, cracks and other defects of ferromagnetic plates or pipeline. A PMFL sensor with new structure is proposed based on the simulation for a variety of different structure sensors. It reduces the magnetic field compression of the background noise to the magnetic flux leakage signal and improves the information accuracy of defects. It is suitable for detecting defect under insulating layer or coating layer. The new structure sensor is developed and the standard samples are tested using it. The experiments validated the correctness and effectiveness of the new sensor.
ISSN:1091-5281
DOI:10.1109/IMTC.2011.5944080