Yet another antenna efficiency measurement method in reverberation chambers

Radiation efficiency is one of the most difficult to measure quantities of antennas. Established methods are mostly either based on the Weehler-Cap-Method and limited to small antenna, or require a full 3D scan around he antenna under test. We present an alternative method for the measurement of ant...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Krauthauser, Hans Georg, Herbrig, M
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Radiation efficiency is one of the most difficult to measure quantities of antennas. Established methods are mostly either based on the Weehler-Cap-Method and limited to small antenna, or require a full 3D scan around he antenna under test. We present an alternative method for the measurement of antenna efficiency in the reverberation chamber. The measurement is based on an emission measurement method presented in [1]. Using this method, antenna efficiencies can be estimated along with the emission measurement of the equipment under test (EUT). This can help to reduce the uncertainty during radiated emission testing in the reverberation chamber. Of course, the method can also be used without an EUT present in the chamber to characterize the antenna only.
ISSN:2158-110X
2158-1118
DOI:10.1109/ISEMC.2010.5711333