Catastrophic short and open fault detection in MOS current mode circuits: A case study

In this paper, the issue of testing analog MOS current mode circuits for catastrophic open and short faults has been addressed. A case study based on the 6-transistor transconductor circuit is discussed. The five-fault model is assumed per transistor, namely a short circuit between any two terminals...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Madian, A H, Amer, H H, Eldesouky, A O
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, the issue of testing analog MOS current mode circuits for catastrophic open and short faults has been addressed. A case study based on the 6-transistor transconductor circuit is discussed. The five-fault model is assumed per transistor, namely a short circuit between any two terminals as well as an open-circuited drain or source. DC testing is performed in order to reduce test cost instead of AC testing which requires expensive equipments. Only one fault is assumed to exist in the circuit under test. PSpice simulations have been carried out using the 0.18μm MOS model provided from MOSIS. The circuit has been simulated for fault-free condition and after injecting a single fault at a time into the circuit. The simulation results have been analyzed and compared. It is found that the total fault coverage is 93%.