Experimental Verification of Deep Field Weakening Operation of a 50-kW IPM Machine by Using Single Current Regulator

This paper analyzes critical control issues associated with the deep field weakening operation of interior permanent magnet (IPM) synchronous machines. The singlecurrent-regulator control algorithm is reviewed, which controls the d -axis current actively and gives a fixed q -axis voltage command. To...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industry applications 2011-01, Vol.47 (1), p.128-133
Hauptverfasser: Zhang, Yuan, Xu, Longya, Guven, Mustafa K., Chi, Song, Illindala, Mahesh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper analyzes critical control issues associated with the deep field weakening operation of interior permanent magnet (IPM) synchronous machines. The singlecurrent-regulator control algorithm is reviewed, which controls the d -axis current actively and gives a fixed q -axis voltage command. To achieve better operational efficiency and performance, improvements are made to choose an optimal q -axis voltage for variable-speed and variable-load conditions. The control algorithm is implemented on a 50-kW IPM machine. Test results, including 7:1 constant power speed ratio operation, are presented to verify the theoretical analysis.
ISSN:0093-9994
1939-9367
DOI:10.1109/TIA.2010.2091478