Sliding Window Trend Analysis: A Method for Short and Open Circuit Detection in Copper Electrorefining
This work presents a system to detect short and open circuits suitable for Optibar ® inter-cell bars in copper electrorefining processes. The system is based in Optibar's voltage connecting segments. Voltages are sampled and transmitted via WI-FI to a compatible SQL database every five minutes....
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This work presents a system to detect short and open circuits suitable for Optibar ® inter-cell bars in copper electrorefining processes. The system is based in Optibar's voltage connecting segments. Voltages are sampled and transmitted via WI-FI to a compatible SQL database every five minutes. The technique proposed performs sliding window analysis on anode-cathode voltages slopes to detect short and open circuits. The system was implemented in a refinery section of 20 cells with 1,100 cathodes. |
---|---|
ISSN: | 0197-2618 2576-702X |
DOI: | 10.1109/IAS.2010.5615654 |