Calculation of unbalanced magnetic pull in a salient-pole synchronous generator
The unbalanced magnetic forces which act upon the rotor of a salient-pole synchronous generator due to eccentric motion of the rotor shaft in the presence of magnetic field originating from the field current in no-load operation have been calculated using finite-element method. The displacement of t...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The unbalanced magnetic forces which act upon the rotor of a salient-pole synchronous generator due to eccentric motion of the rotor shaft in the presence of magnetic field originating from the field current in no-load operation have been calculated using finite-element method. The displacement of the rotor has been modeled using the actual shaft orbit recorded on a 5 MVA salient-pole generator driven by a gas turbine in a cogeneration plant. The results indicate that a variation of unbalanced forces in no-load operation at rated voltage occurs at the precession frequency of 25 Hz with maximum force of 2.32 kN. |
---|---|
DOI: | 10.1109/EPEPEMC.2010.5606602 |