Calculation of unbalanced magnetic pull in a salient-pole synchronous generator

The unbalanced magnetic forces which act upon the rotor of a salient-pole synchronous generator due to eccentric motion of the rotor shaft in the presence of magnetic field originating from the field current in no-load operation have been calculated using finite-element method. The displacement of t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zarko, D, Ban, D, Vazdar, I, Jaric, V
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The unbalanced magnetic forces which act upon the rotor of a salient-pole synchronous generator due to eccentric motion of the rotor shaft in the presence of magnetic field originating from the field current in no-load operation have been calculated using finite-element method. The displacement of the rotor has been modeled using the actual shaft orbit recorded on a 5 MVA salient-pole generator driven by a gas turbine in a cogeneration plant. The results indicate that a variation of unbalanced forces in no-load operation at rated voltage occurs at the precession frequency of 25 Hz with maximum force of 2.32 kN.