Storage systems based on scanning probe microscopy incorporate an array of thermopiezoelectric cantilevers that require charge amplifiers with a wide frequency response but low power consumption. We use an improved frequency compensation method to enhance the in-band frequency response without requi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on circuits and systems. II, Express briefs Express briefs, 2010-09, Vol.57 (9), p.691-695
Hauptverfasser: Lee, Hyunjoong, Woo, Jong-Kwan, Nam, Hyo-Jin, Jin, Won-Hyeog, Jeong, Moongi, Kim, Young-Sik, Shin, Jin-Koog, Kim, Suhwan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Storage systems based on scanning probe microscopy incorporate an array of thermopiezoelectric cantilevers that require charge amplifiers with a wide frequency response but low power consumption. We use an improved frequency compensation method to enhance the in-band frequency response without requiring any additional power. Measurements show that the prototype chip draws the same 68 A at 1.8 V as an unmodified design but has a closed-loop frequency response that is ten times greater. The chip was fabricated in a 0.18-m standard CMOS process, and the charge amplifier core occupies 0.042 mm 2 .