Establishment of 40,000 A Rogowski coil calibration system and its uncertainty analysis

System for calibrating Rogowski coil(RC) up to primary current of 40,000 A have been established by employing standard current transformer(CT), CT comparator and voltage to current converter(VCC). The expanded uncertainty is 0.021 % ~ 0.230 % for ratio error and 0.3 min ~ 1.9 min for phase displacem...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Yoon Hyoung Kim, Jae Kap Jung, Jeon Hong Kang, Sang Hwa Lee, Sang Ok Han
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:System for calibrating Rogowski coil(RC) up to primary current of 40,000 A have been established by employing standard current transformer(CT), CT comparator and voltage to current converter(VCC). The expanded uncertainty is 0.021 % ~ 0.230 % for ratio error and 0.3 min ~ 1.9 min for phase displacement in the primary current ranges of 10 ~ 40,000 A.
ISSN:0589-1485
2160-0171
DOI:10.1109/CPEM.2010.5544155