Optimization of Calibration Parameters for Hybrid III 5th Female Dummy Neck Calibration Based on Taguchi Method

The costly honeycomb used in Hybrid III 5 th female dummy neck calibration experiments and the lower rate of successful experiments because of there are many factors affecting neck deceleration characteristic will cause much waste of manpower and finance. We found from lots of tests that calibration...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zhixin Liu, Xiaolong Zhang, Hong Chen, Yongwan Shi
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The costly honeycomb used in Hybrid III 5 th female dummy neck calibration experiments and the lower rate of successful experiments because of there are many factors affecting neck deceleration characteristic will cause much waste of manpower and finance. We found from lots of tests that calibration temperature, impact velocity of the pendulum, cells of honeycomb and its cut style would affect the calibration results greatly. In this paper we adopted Taguchi method to determine the optimal levels of these factors, combined with S/N ratio and analysis of variance (ANOVA) to discuss the trends how these factors affect the calibration results. Finally we got the optimized parameters of Hybrid III 5 th female neck calibration.
ISSN:2160-7443
DOI:10.1109/ICIC.2010.295