Receiver as a radiometer calibration target
What is proposed in this paper as a new, novel idea is to use the input port of a complete radiometer receiver as a calibration target instead of a dedicated Active Cold Load (ACL). What is also proposed is to use the input port as a phase calibration target as well. Modern LNA technology has made v...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | What is proposed in this paper as a new, novel idea is to use the input port of a complete radiometer receiver as a calibration target instead of a dedicated Active Cold Load (ACL). What is also proposed is to use the input port as a phase calibration target as well. Modern LNA technology has made very low noise figures and return losses possible; both key parameters for a cold and stable ACL. Low noise figure and good matching combined with a typical high isolation of an amplifier makes it possible to use a receiver itself as a cold calibration target. This is beneficial in instruments inherently having (at least) two receivers (pushbroom or polarimetric radiometer for example). |
---|---|
ISSN: | 2153-6996 2153-7003 |
DOI: | 10.1109/IGARSS.2009.5417358 |