Research on Biological Contact Oxidation Process Treating Simulated Ship Sewage
In this paper, pilot-scale test of biological contact oxidation process for simulated ship sewage treatment was carried out. The results showed that under the condition of HRT=3.5h, T=25~30°C, pH=6.8±0.5, and the average concentrations of COD Cr , BOD 5 , SS and NH4+-N in the influent were 597.8mg/L...
Gespeichert in:
Hauptverfasser: | , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, pilot-scale test of biological contact oxidation process for simulated ship sewage treatment was carried out. The results showed that under the condition of HRT=3.5h, T=25~30°C, pH=6.8±0.5, and the average concentrations of COD Cr , BOD 5 , SS and NH4+-N in the influent were 597.8mg/L, 371.8mg/L, 369mg/L and 33.52mg/L, respectively, the concentrations of COD Cr , BOD 5 , SS, NH4+-N in the effluent were 90.0mg/L, 38.5mg/L, 59mg/L , 4.66mg/L, and the average removal rates of COD Cr , BOD 5 , SS, NH4+-N were 85.0%, 89.6%, 83.9% and 86.0%, respectively. The results indicated that biological contact oxidation process had good effect on ship sewage treatment and can meet the needs of practical application. |
---|---|
DOI: | 10.1109/ICEET.2009.408 |