Elimination of magnetic saturation due to fast dynamic response in DC-DC converter
Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. Core saturation presented here is observed in onboard isolated DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is n...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 6 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | |
creator | Kohama, T. Tokimatsu, S. Shimamori, H. |
description | Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. Core saturation presented here is observed in onboard isolated DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Method for eliminating magnetic saturation is also presented. Effectiveness of proposed method is confirmed by experiments. |
doi_str_mv | 10.1109/INTLEC.2009.5351916 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_5351916</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5351916</ieee_id><sourcerecordid>5351916</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-e6323f05e3d0ac2dba656769f8fa4cb453b8a2d3aa9d614e2159a32eb0d2a6923</originalsourceid><addsrcrecordid>eNpFUNtqwkAU3F4ErfULfNkfiD17TfaxRNsK0kLxXU6yJ2WL2UiyFvz7Bip0GDgwA8OcYWwpYCUEuKft-363KVcSwK2MMsIJe8MehJZ6pBP5LZtJYYrMSAF3_wa4ezYDmZsMdK4mbFoU1lghiylbDMM3jNAGLJgZ-9wcQxsiptBF3jW8xa9IKdR8wHTu_2R_Jp463uCQuL9EbEe7p-HUxYF4iHxdZuuS1138oT5R_8gmDR4HWlzvnO1fNvvyLdt9vG7L510WHKSMrJKqAUPKA9bSVzhWzK1rigZ1XWmjqgKlV4jOW6Fp_NOhklSBl2idVHO2_IsNRHQ49aHF_nK4rqR-AVb0VgQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Elimination of magnetic saturation due to fast dynamic response in DC-DC converter</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Kohama, T. ; Tokimatsu, S. ; Shimamori, H.</creator><creatorcontrib>Kohama, T. ; Tokimatsu, S. ; Shimamori, H.</creatorcontrib><description>Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. Core saturation presented here is observed in onboard isolated DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Method for eliminating magnetic saturation is also presented. Effectiveness of proposed method is confirmed by experiments.</description><identifier>ISSN: 0275-0473</identifier><identifier>ISBN: 1424424909</identifier><identifier>ISBN: 9781424424900</identifier><identifier>EISSN: 2158-5210</identifier><identifier>EISBN: 1424424917</identifier><identifier>EISBN: 9781424424917</identifier><identifier>DOI: 10.1109/INTLEC.2009.5351916</identifier><identifier>LCCN: 88656128</identifier><language>eng</language><publisher>IEEE</publisher><subject>Capacitors ; Circuit faults ; DC-DC power converters ; Magnetic circuits ; Magnetic cores ; Power supplies ; Pulse width modulation ; Pulse width modulation converters ; Saturation magnetization ; Transformer cores</subject><ispartof>INTELEC 2009 - 31st International Telecommunications Energy Conference, 2009, p.1-6</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5351916$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,780,784,789,790,2056,27923,54918</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5351916$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Kohama, T.</creatorcontrib><creatorcontrib>Tokimatsu, S.</creatorcontrib><creatorcontrib>Shimamori, H.</creatorcontrib><title>Elimination of magnetic saturation due to fast dynamic response in DC-DC converter</title><title>INTELEC 2009 - 31st International Telecommunications Energy Conference</title><addtitle>INTLEC</addtitle><description>Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. Core saturation presented here is observed in onboard isolated DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Method for eliminating magnetic saturation is also presented. Effectiveness of proposed method is confirmed by experiments.</description><subject>Capacitors</subject><subject>Circuit faults</subject><subject>DC-DC power converters</subject><subject>Magnetic circuits</subject><subject>Magnetic cores</subject><subject>Power supplies</subject><subject>Pulse width modulation</subject><subject>Pulse width modulation converters</subject><subject>Saturation magnetization</subject><subject>Transformer cores</subject><issn>0275-0473</issn><issn>2158-5210</issn><isbn>1424424909</isbn><isbn>9781424424900</isbn><isbn>1424424917</isbn><isbn>9781424424917</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNpFUNtqwkAU3F4ErfULfNkfiD17TfaxRNsK0kLxXU6yJ2WL2UiyFvz7Bip0GDgwA8OcYWwpYCUEuKft-363KVcSwK2MMsIJe8MehJZ6pBP5LZtJYYrMSAF3_wa4ezYDmZsMdK4mbFoU1lghiylbDMM3jNAGLJgZ-9wcQxsiptBF3jW8xa9IKdR8wHTu_2R_Jp463uCQuL9EbEe7p-HUxYF4iHxdZuuS1138oT5R_8gmDR4HWlzvnO1fNvvyLdt9vG7L510WHKSMrJKqAUPKA9bSVzhWzK1rigZ1XWmjqgKlV4jOW6Fp_NOhklSBl2idVHO2_IsNRHQ49aHF_nK4rqR-AVb0VgQ</recordid><startdate>200910</startdate><enddate>200910</enddate><creator>Kohama, T.</creator><creator>Tokimatsu, S.</creator><creator>Shimamori, H.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200910</creationdate><title>Elimination of magnetic saturation due to fast dynamic response in DC-DC converter</title><author>Kohama, T. ; Tokimatsu, S. ; Shimamori, H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-e6323f05e3d0ac2dba656769f8fa4cb453b8a2d3aa9d614e2159a32eb0d2a6923</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Capacitors</topic><topic>Circuit faults</topic><topic>DC-DC power converters</topic><topic>Magnetic circuits</topic><topic>Magnetic cores</topic><topic>Power supplies</topic><topic>Pulse width modulation</topic><topic>Pulse width modulation converters</topic><topic>Saturation magnetization</topic><topic>Transformer cores</topic><toplevel>online_resources</toplevel><creatorcontrib>Kohama, T.</creatorcontrib><creatorcontrib>Tokimatsu, S.</creatorcontrib><creatorcontrib>Shimamori, H.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kohama, T.</au><au>Tokimatsu, S.</au><au>Shimamori, H.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Elimination of magnetic saturation due to fast dynamic response in DC-DC converter</atitle><btitle>INTELEC 2009 - 31st International Telecommunications Energy Conference</btitle><stitle>INTLEC</stitle><date>2009-10</date><risdate>2009</risdate><spage>1</spage><epage>6</epage><pages>1-6</pages><issn>0275-0473</issn><eissn>2158-5210</eissn><isbn>1424424909</isbn><isbn>9781424424900</isbn><eisbn>1424424917</eisbn><eisbn>9781424424917</eisbn><abstract>Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. Core saturation presented here is observed in onboard isolated DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Method for eliminating magnetic saturation is also presented. Effectiveness of proposed method is confirmed by experiments.</abstract><pub>IEEE</pub><doi>10.1109/INTLEC.2009.5351916</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0275-0473 |
ispartof | INTELEC 2009 - 31st International Telecommunications Energy Conference, 2009, p.1-6 |
issn | 0275-0473 2158-5210 |
language | eng |
recordid | cdi_ieee_primary_5351916 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Capacitors Circuit faults DC-DC power converters Magnetic circuits Magnetic cores Power supplies Pulse width modulation Pulse width modulation converters Saturation magnetization Transformer cores |
title | Elimination of magnetic saturation due to fast dynamic response in DC-DC converter |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T16%3A24%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Elimination%20of%20magnetic%20saturation%20due%20to%20fast%20dynamic%20response%20in%20DC-DC%20converter&rft.btitle=INTELEC%202009%20-%2031st%20International%20Telecommunications%20Energy%20Conference&rft.au=Kohama,%20T.&rft.date=2009-10&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.issn=0275-0473&rft.eissn=2158-5210&rft.isbn=1424424909&rft.isbn_list=9781424424900&rft_id=info:doi/10.1109/INTLEC.2009.5351916&rft_dat=%3Cieee_6IE%3E5351916%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424424917&rft.eisbn_list=9781424424917&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5351916&rfr_iscdi=true |