Elimination of magnetic saturation due to fast dynamic response in DC-DC converter

Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. Core saturation presented here is observed in onboard isolated DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is n...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kohama, T., Tokimatsu, S., Shimamori, H.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. Core saturation presented here is observed in onboard isolated DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Method for eliminating magnetic saturation is also presented. Effectiveness of proposed method is confirmed by experiments.
ISSN:0275-0473
2158-5210
DOI:10.1109/INTLEC.2009.5351916