High rate large dynamic range analog circuitry and digitizers for fast calorimetry

This paper describes the issues encountered in the design of a large dynamic range digitizer for calorimetry. A gain switching technology developed for the liquid krypton calorimeter of the NA48 CP-violation experiment at CERN is described in detail. 14 bit dynamic range and better than 300 ps time...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE Transactions on Nuclear Science 1996-06, Vol.43 (3), p.1605-1609
Hauptverfasser: Hallgren, B., Bal, F., Barr, G.D., Buchholz, P., Formenti, F., Funk, W., Kozhevnikov, Yu, Lacourt, A., Laverriere, G., Martini, M., Papi, A., Ponting, P., Sozzi, M., Vossnack, O., Wahl, H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper describes the issues encountered in the design of a large dynamic range digitizer for calorimetry. A gain switching technology developed for the liquid krypton calorimeter of the NA48 CP-violation experiment at CERN is described in detail. 14 bit dynamic range and better than 300 ps time resolution were achieved in beam tests with an 8 channel prototype. A mixed analog/digital ASIC has been developed. A 13,500 channel system is being produced which will be put into operation in 1996.
ISSN:0018-9499
1558-1578
DOI:10.1109/23.507155