Simulating multi-connection, three-phase, squirrel-cage, induction motors by means of changing the per-phase equivalent circuit parameters
In this paper, considerations on the simulation of single-speed, multi-connection (or multi-flux level), three-phase, squirrel-cage, induction motors using the per-phase exact equivalent circuit, with fixed voltage, are discussed. The principles discussed also apply to simple star-delta connection c...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, considerations on the simulation of single-speed, multi-connection (or multi-flux level), three-phase, squirrel-cage, induction motors using the per-phase exact equivalent circuit, with fixed voltage, are discussed. The principles discussed also apply to simple star-delta connection change. Simulated and experimental results are presented, validating the proposed simulation strategy and, additionally, evidencing the advantages associated with the stator winding connection change as a function of the motor actual load. |
---|---|