In-Beam and Off-Beam PET Measurements of Target Activation by Megavolt X-Ray Beams

In-beam positron emission tomography (in-beam PET) is a valuable in situ method for quality assurance in radiation therapy. It is well investigated for therapy with carbon ions and has been successfully implemented clinically at the Gesellschaft for Schwerionenforschung (GSI), Darmstadt, Germany. Th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2009-02, Vol.56 (1), p.57-65
Hauptverfasser: Kunath, D., Kluge, T., Pawelke, J., Priegnitz, M., Enghardt, W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In-beam positron emission tomography (in-beam PET) is a valuable in situ method for quality assurance in radiation therapy. It is well investigated for therapy with carbon ions and has been successfully implemented clinically at the Gesellschaft for Schwerionenforschung (GSI), Darmstadt, Germany. The extension of this efficient technique to other radiation treatment modalities may be worthwhile. For protons, 3 He, 7 Li, and 16 O the feasibility has already been experimentally shown. Furthermore, it seems to be feasible for the case of radiotherapy with high-energy photons, since positron emitters are generated by photons with energies above ~ 20 MeV due to (gamma, n ) photo-nuclear reactions (predominantly 11 C and 15 O in tissue). In this regard, promising conclusions have been obtained by Geant4 simulations as well as by off-beam PET experiments using a conventional PET scanner. The next step was the installation of a small double head positron camera consisting of two bismuth germanate (BGO) block detectors at the irradiation site to measure the generated beta + activity distribution simultaneously to the irradiation. The relation between deposited dose and beta + activity density was quantified. The obtained results are presented and compared to that of off-beam PET experiments. Higher activities as well as an improved contrast between materials of different stoichiometry are achieved by measuring in-beam, showing the advantage of in-beam PET over off-beam PET. Thus, the application of in-beam PET to radiation therapy with high-energy photons can be useful for quality assurance, comprising monitoring of dose delivery, patient positioning and tumor response.
ISSN:0018-9499
1558-1578
DOI:10.1109/TNS.2008.2007422