MSGCROC - an ASIC for high count rate readout of position sensitive Microstrip Gas Chambers for thermal neutrons

In this paper we report on the development of an ASIC for readout of position sensitive neutron detectors based on low-pressure Micro-Strip Gas Chambers with solid composite 157 Gd/CsI converter. Global counting rates of 10 8 cps for a detector area of 25×25 cm 2 covered with 400×400 strips requirin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Brogna, Andrea S., Buzzetti, Siro, Dabrowski, Wladyslaw, Fiutowski, Tomasz, Gebauer, Burckhard, Mindur, Bartosz, Schmidt, Christian J., Schulz, Christian, Soltveit, Hans K., Szczygiel, Robert, Trunk, Ulrich, Wiacek, Piotr
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper we report on the development of an ASIC for readout of position sensitive neutron detectors based on low-pressure Micro-Strip Gas Chambers with solid composite 157 Gd/CsI converter. Global counting rates of 10 8 cps for a detector area of 25×25 cm 2 covered with 400×400 strips requiring 2 ns time resolution for coincidences of signals from X- and Y-strips set very demanding requirements for the ASIC performance.
ISSN:1082-3654
2577-0829
DOI:10.1109/NSSMIC.2008.4774695